V100 Structural Steel Profile Laser Cutting Machine selection starts with the section drawing, clamping conditions and incoming stock. The published table identifies manual loading, a Loading Length of 12000mm and a Maximum Single-Workpiece Load Capacity of no more than 5T. These are separate fields to retain in a project specification.

Build the enquiry around the profiles that actually need processing. A section designation alone may leave the wall dimensions, finished features and handling requirement unclear. Send the section drawing with the incoming length and workpiece mass, then identify the features and dimensional results required from the finished component.

Request a quote

info@victoryindustrytrade.com

Technical specifications

V100 Structural Steel Profile Laser Cutting Machine — technical specifications
SpecificationConfiguration
ItemParameter
Tube Processing RangeRound tubes: dia. 150-1000 mm; Square tubes: 150 x 150-850 x 850 mm; I-beams and H-beams channel steel: 10#-85#
X/Y-Axis Positioning Accuracy±0.05 mm/1000 mm
X/Y-Axis Repeat Positioning Accuracy+/-0.05 mm
Maximum X-Axis Travel1050 mm
Maximum Y-Axis Travel13920 mm
Maximum Z-Axis Travel700 mm
Maximum B-Axis Travel+/-360 deg
Maximum A-Axis Travel+/-45 deg
Maximum Acceleration0.2G
Minimum Clamping Wall Thickness≥5.0 mm
Maximum Single-Workpiece Load Capacity≤5T
Loading MethodManual loading
Loading Length12000 mm
Host Size (L x W x H)approx. 23195 x 4135 x 4000 mm
Weightapprox. 13.5T
Power Supply/Voltage Frequency3 / 380V (+/-10%) / 50Hz
Main Power Protection LevelIP54

Configuration options vary by model. Confirm the final specification, selected components and operating requirements with your quotation.

V100 configuration options

The Tube Processing Range lists round tubes at dia. 150-1000mm and square tubes at 150 x 150-850 x 850mm. It also gives the combined entry I-beams and H-beams channel steel at 10#-85#. Keep the exact section drawing alongside that entry so the proposed profile is identified without guessing how an abbreviated designation applies.

Minimum Clamping Wall Thickness is listed as at least 5.0mm. This is a clamping field, distinct from the maximum single-workpiece load entry of no more than 5T. Provide wall dimensions and workpiece mass separately. A clamping-thickness value should not be relabeled as a tested cutting-thickness capacity for your material.

The table gives Maximum X-Axis Travel of 1050mm, Y-Axis Travel of 13920mm and Z-Axis Travel of 700mm. Loading Length remains 12000mm. Keep travel and loading labels intact in the enquiry, since replacing one with the other would change the stated requirement rather than clarify it.

V100 workpiece requirements

For V100 workpiece requirements, create one record for each representative section. Include the profile drawing, material specification, incoming length, wall dimensions, mass and finished features. Mark any critical locations directly on the drawing. Distinguish current work from provisional sections so that an unanswered future requirement is not treated as an agreed configuration.

Imagine a project that already has equipment for moving long stock. Show how that equipment is intended to approach the proposed machine and where finished pieces need to go. The source states manual loading; any different requested handling arrangement should have its own description and supply scope in the proposal.

V100 quotation details

Host Size is approximately 23195 x 4135 x 4000mm, and Weight is approximately 13.5T in the published table. Use these qualified figures as references when requesting the installation drawing. Ask for the external arrangement and necessary access information for the offered equipment before finalizing the position on a site plan.

The Power Supply/Voltage Frequency entry is 3 / 380V (+/-10%) / 50Hz. Main Power Protection Level is listed as IP54. Keep both under their original labels when gathering installation information. The V100 table has no Laser Power row, so the proposed laser configuration needs a specific response rather than a value borrowed from another range.

X/Y-Axis Positioning Accuracy is listed as ±0.05mm/1000mm and Repeat Positioning Accuracy as +/-0.05mm. State the finished-component requirements separately with the relevant dimensions marked. A complete quotation brief should connect those requirements to the section, clamping information, handling plan and clearly identified equipment scope.

Product questions

What should define a V100 configuration enquiry?

Start with the actual section drawing, incoming length, wall dimensions and workpiece mass, then identify finished features and the handling arrangement that needs to be discussed.

Does the 5.0mm field specify cutting thickness?

The source labels it Minimum Clamping Wall Thickness and gives ≥5.0mm. Retain that meaning; it is not a material-specific cutting-thickness result.

Are Loading Length and Y-Axis Travel interchangeable?

No. Loading Length is 12000mm, while Maximum Y-Axis Travel is 13920mm. They describe separate specification fields.

Does manual loading include an automatic handling package?

The stated method is manual loading. A requested alternative needs an explicit equipment description and supply scope in the proposal.

Which laser power should be put into the enquiry?

The published V100 table does not specify laser power. Ask the proposal to identify the actual configuration against your requirements instead of transferring a rating from another series.

Related equipment and information

Browse configurations

Discuss V100 requirements

Published product reference

Ready to discuss V100 Structural Steel Profile Laser Cutting Machine?

Share your material, dimensions and process. Start a conversation about the right configuration.